Connections

Warning! Read 'Safety' starting on page 4 before connecting the
impression X5 to power.

AC power

The impression X5 has a Neutrik powerCON TRUE1 socket for connection to AC mains
power from a Neutrik powerCON TRUE1 female cable connector. The autosensing
power supply accepts 100-240 V, 50/60 Hz AC power. Do not connect the fixture to
AC power at any other voltage.
The AC mains power distribution circuit must include a connection to ground /
protective earth. It must be protected against ground / earth leakage and overload.
Do not connect the fixture to a power distribution circuit that is equipped with an
external dimmer.
Powering the fixture on
The fixture does not have an ON/OFF switch. It is powered on as soon as power is
applied to the power input cable. Before applying power, check that the head is
unlocked, check that the head will not collide with anything, and check that nobody
will be looking directly at the fixture if it lights up suddenly.
Connecting to power
Although powerCON TRUE1 connectors support hot-plugging, it is still good practice
to shut down power to power cables before connecting them to fixtures.
To connect the fixture to power:
Check that the Neutrik powerCON TRUE1 connector on the power input cable is
in perfect condition, paying attention to the keys on the connector. If the
connector or its keys show signs of damage, replace the connector with a new
item.
Line up the keys in the TRUE1 connector correctly with the keyways in the MAINS
IN socket.
Insert the connector into the socket. Do not use force. If you feel any more than
light resistance when you try to push the connector into the socket, something is
wrong. You may have lined up keys and keyways incorrectly. Remove the
connector and check the positions of keys and keyways before trying to insert the
connector again.
Twist the connector fully clockwise to lock. Listen for a 'click' that indicates that
the connector is locked.
Release the tilt lock, check the clearance around the head and make sure that
nobody is looking directly at the fixture. Then apply power to the power input
cable.