Advertisement

Quick Links

PSU12
from software version: v1.21
support@glp.de
www.glp.de

Advertisement

Table of Contents
loading

Summary of Contents for GLP X4 atom PSU 12

  • Page 1 PSU12 from software version: v1.21 support@glp.de www.glp.de...
  • Page 2: Table Of Contents

    GLP German Light Products Contents Description of Device ..................... 3 Safety Instructions ......................4 Mounting .......................... 5 Operating on the floor, on a table or in a Rack ..........5 Mounting in a hanging or sideways position ............5 Securing the Fixture ....................6 Connections ........................
  • Page 3: Description Of Device

    GLP German Light Products 1 Description of Device 1. LCD-Display / Menu (data entry) 2. Safety wire attachment point (2x) 3. Fan in/outlet (2x) 4. Connector panel (see below) Connector Panel 5. Mains switch (on / off) 9. Mains Input (blue powerCON) 6.
  • Page 4: Safety Instructions

    4. To ensure safe operation, follow also the Installation guide described in the chapter below. Operating the X4 ATOM PSU 12 without suitable safety aids like Safety cables or clamps/hooks can increase the risk of an accident and must be avoided.
  • Page 5: Mounting

    3.1 Operating on the floor, on a table or in a Rack The X4 ATOM PSU 12 can directly placed on the floor, a table or inside a rack. An additional securing is usually not required. Please pay attention to an even and gripping surface and keep at least 10cm space to each side for ventilation.
  • Page 6: Securing The Fixture

    1 x M10 x 11mm thread bolt 3.3 Securing the Fixture Regardless of the mounting method of the X4 ATOM PSU 12 you'll have to use a stipulated safety wire. Attach the safety wire through the attachment point shown below and connect it to the primary support structure.
  • Page 7: Connections

    Always disconnect from the mains supply for changing the fuse and use only the above described micro-fuse type. NEUTRIK® powerCON The X4 ATOM PSU 12 is fitted with NEUTRIK® powerCON locking 3 conductor AC connectors. The grey connector must be used to draw AC mains power from the fixtures` throughput sockets and the blue connectors must be used to supply power at the fixtures` power input socket.
  • Page 8: Dmx

    Do not exceed 60m / 200ft. cable length for any output to the X4 ATOM head. Attention: Do only connect one (1) GLP X4 ATOM head per output. Never connect any other equipment to this output as this may damage the PSU and/or the connected fixture(s).
  • Page 9 GLP German Light Products Fixture Select fixture/output Zoom Manual control for zoom Speed Movements Special Manual control for Special functions White Manual control for Color temperature Temperature Dimmer Manual control for Dimmer Shutter Manual control for Shutter White Manual control for White...
  • Page 10 GLP German Light Products Master Instantaneous value for Master Intensity Intensity Fixture Instantaneous value for Fixture Sel. Zoom Instantaneous value for Zoom Speed Movements Special Instantaneous value for Special White Adjustment of the color temperature Temperature Dimmer Instantaneous value for Dimmer...
  • Page 11: Dmx Channel Selection (Dmx Protocol)

    GLP German Light Products 6 DMX Channel Selection (DMX Protocol) 6.1 Normal Mode (norm) 110 DMX Channels: Note: We suggest to patch the Atom PSU as one 2 channel fixture and each connected Atom head as one 9 channel fixture.
  • Page 12 GLP German Light Products White - CTB 7200K 47..49 120..127 Rainbow Effect Stop Rainbow Effect slow - fast 51..88 129..223 Random colors slow - fast 89..100 224..255 Color mixing system - Red 0 - 100% 0..100 0..255 Green Color mixing system - Green 0 - 100% 0..100...
  • Page 13 GLP German Light Products Output 3 Intensity Intensity 0 - 100% 0..100 0..255 Shutter 0..5 0..15 Shutter closed random / slow - fast 6..18 16..47 Random strobe random / slow - fast 19..31 48..79 Ramp up random / slow - fast 32..43...
  • Page 14 GLP German Light Products Color 10 - Malve 31..34 80..87 Color 11 - Magenta 35..37 88..95 Color 12 - Pink 38..40 96..103 White - CTO 3200K 41..43 104..111 White 5600K 44..46 112..119 White - CTB 7200K 47..49 120..127 Rainbow Effect Stop...
  • Page 15 GLP German Light Products random / slow - fast 6..18 16..47 Random strobe random / slow - fast 19..31 48..79 Ramp up random / slow - fast 32..43 80..111 Ramp down random / slow - fast 44..62 112..143 Pulse random / slow - fast 63..77...
  • Page 16 GLP German Light Products White - CTO 3200K 41..43 104..111 White 5600K 44..46 112..119 White - CTB 7200K 47..49 120..127 Rainbow Effect Stop Rainbow Effect slow - fast 51..88 129..223 Random colors slow - fast 89..100 224..255 Color mixing system - Red 0 - 100% 0..100...
  • Page 17 GLP German Light Products random / slow - fast 44..62 112..143 Pulse random / slow - fast 63..77 144..199 Strobe with b/o pause random / slow - fast 78..98 200..239 Strobe - Slow to Fast 95..100 239..255 Shutter Open Color (fixed) Colors adjustable via RGB 0..2...
  • Page 18 GLP German Light Products Rainbow Effect Stop Rainbow Effect slow - fast 51..88 129..223 Random colors slow - fast 89..100 224..255 Color mixing system - Red 0 - 100% 0..100 0..255 Green Color mixing system - Green 0 - 100% 0..100...
  • Page 19 GLP German Light Products 95..100 239..255 Shutter Open 104 Color (fixed) Colors adjustable via RGB 0..2 0..7 Color 01 - Red 3..5 8..15 Color 02 - Amber 6..8 16..23 Color 03 - Warm Yellow 9..12 24..31 Color 04 - Yellow 13..15...
  • Page 20: Maintaining And Cleaning

    GLP German Light Products 7 Maintaining and Cleaning The X4 ATOM PSU 12 is a fixture of very low maintenance. It is only necessary to clean the air inlets and outlets from time to time. For safe operation it is absolutely essential that the fixture is kept clean and that dust, dirt and smoke- fluid residues must not build up on, or within the fixture.
  • Page 21: Technical Specifications

    GLP German Light Products 8 Technical Specifications: Power supply Power consumption Max. 350 VA (Watt) / 25VA (Watt) per X4 Atom head Power input Auto sensing 90-240 V AC, 50-60 Hz Mains in connector PowerCON (blue) max 20A Mains out connector...
  • Page 22: Dimensions

    GLP German Light Products 9 Dimensions X4 Atom PSU12 manual (v1.0) from software version: v1.21...
  • Page 23 GLP German Light Products X4 Atom PSU12 manual (v1.0) from software version: v1.21...

Table of Contents