2.2 Securing the Device

Regardless of the mounting method of the
a secondary safety wire. This safety wire can be attached to the fixture by
threading it through one of the two holes provided on the base of the fixture.
Ensure that the safety wire is securely fastened through the fixture and the
fixtures mounting support. Install a safety wire that can hold at least 10 times
the weight of the fixture

2.3 Connections

2.3.1 Power Supply

~100-240 Volt AC, 50-60 Hz, earth contact type plug - Powercon
Connected load 1200 VA (W) <=> T15A (micro-fuse 6.3x32mm)
Please see printing on the case for the correct mains supply!
Disconnect from the mains supply for changing the fuse and use
only the above described micro-fuse type.

2.3.2 DMX

USITT DMX-512 Standard input/output in 3 pole and 5 pole connectors.
3 pole: Pin 1 = [Ground] / Pin 2 = [-] / Pin 3 = [+]
5 pole: Pin 1 = [Ground] / Pin 2 = [-] / Pin 3 = [+] / Pin 4/5 n.c.
The DMX- Addressing starts at the DMX- Address [001].