Configuration in the WBM
dustrial managed switch and/or it can be sent to a remote log server. The user needs to
select the log level and provides the IP address of a remote log server and the service
port of the log server. Please click on the [Submit] button after finishing the setup. Table
"WBM "Diagnostics" Page – "System Log" – "Setting" Tab" summarizes the descriptions
of the Syslog Settings' parameters.
Parameters
Enable Log Event to
Flash
Log Level (Protokoll-
ebene)
Enable Syslog
Server
Syslog Server IP
Syslog Server Ser-
vice Port
56
Product manual | Version: 1.2.0
Industrial Managed Switch
Figure 40: WBM "Diagnostics" Page – "System Log" – "Setting" Tab
Table 28: WBM "Diagnostics" Page – "System Log" – "Setting" Tab
Factory Default
Description
Uncheck
Checked: Saving log event into flash memory. The flash memory
can keep the log event files even if the switch is rebooted.
Unchecked: Saving log event into RAM memory. The RAM mem-
ory cannot keep the log event files after each reboot.
3: (LOG_ERR)
Set the log level to determine what events to be displayed on the
next webpage (Log). The level selection is inclusive. For example,
if 3: (Log_ERR) is selected, all 0, 1, 2 and 3 log levels will be im-
plied.
Range from Log  0 to Log 7.
Uncheck
Checked: Enable Syslog Server.
Uncheck: Disable Syslog Server.
If enabled, all recorded log events will be sent to the remote Sys-
tem Log server.
0.0.0.0
Set the IP address of Syslog server.
514
Set the service port number of Syslog server.
Range from Port  1 to Port 65535.