Property
Standards
4.5.5 Environment requirements
Property
Surrounding air temperature, operation
Surrounding air temperature, storage
UL 62368-1 Use
Relative humidity
Vibration resistance
Shock resistance
EMC immunity to interference
EMC Emission of interference
4.6 Guidelines, approvals and standards
4.6.1 Approvals
The following approvals have been granted for the product:
Note
More information on approvals
You can find detailed information on the approvals online at: ü www.wago.com/<item
number>
4.6.2 Regulations and Standards
Please observe the standards and regulations that are relevant to installation:
20
Product manual | Version: 1.2.0
Industrial Managed Switch
Value
IEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX
IEEE 802.3ab 1000BASE-T
IEEE 802.3x Flow Control, back pressure Flow Control
IEEE 802.1Q for VLAN Tagging (Prioritization of Profinet Packets)
IEEE 802.1p for CoS (Prioritization of Profinet Packets)
IEEE 802.1AE for MAC Security
Value
-20 ... +70 °C
-40 ... +85 °C
Indoor
Pollution degree
PD 2
5 ... 95 %, 55 °C
IEC 60068-2-6
IEC 60068-2-27
EN 55024
EN 61000-6-2
EN 61000-6-1
FCC Part 15, Subpart B, Class A,
Class B
EN 55032 Class A and Class B
EN 61000-6-4
EN 61000-6-3
EN 55011
Conformity Marking
Ordinary Locations
Table 12: Technical Data ‒ Environmental Conditions
UL62368 (E482462)
852-1322