2. WIRING
2.4.1
How to connect the processor unit
10S2380 cable
Fabricate the 10S2380 cable as shown in the following cable and pass the cable
through the cable clamp on the transceiver unit, then connect to CN-B101.
Transceiver Unit side
Outer sheath
Vinyl tape
How to connect wires to a terminal connector
Twist
LAN cable
Fabricate the LAN cable (DTIC5E350SLABVCVxxT, max. 100 m) referring to
section 2.2.3, then connect the LAN connector to the CN-B103.
2.4.2
How to connect the junction box
1. Connect the cables from the junction box referring to the cable no. labeled on the
chassis and connector no. labeled on each PC board. Connect the HIF connector
of the cable from the junction box to the TRX board on the transceiver unit.
2. Arrange the cables in numerical order and fix them with the cable clamp.
2-12
480 mm
480 mm
45 mm
45 mm
40 mm
40 mm
Armor Inner sheath
Vinyl tape
Clamp here.
Expose the cores then wind the shield
around the inner sheath.
Press downward.
Terminal
opener
Terminal
connector
Shield
Cores
6 mm
Procedure
1. Twist the cores.
2. Press the terminal opener
downward.
3. Insert the wire in the hole.
4. Remove the terminal
opener.
5. Pull the wire to confirm
that it is secure.