Furuno FSV-25 MARK-2 Installation Manual page 35

Color scanning solar
Table of Contents

Advertisement

• When the transducer is removed from the hull unit while installing the hull unit, re-
attach the transducer and route the transducer cables as shown in the following fig-
ure.
Transducer cable routing layout
View from "A"
Cable fixing plate
(Below one is
attached only for
FSV-254-MK2.)
How to attach the cable clamp
Fastening torque:
2.40 N m
Upset screw
M5×30
Use three screws to secure one cable
clamp.
How to attach the cable fixing rubber
Cross-section view: a-a
Outside routing cable
Slit
Inside routing cable
Attach two cable routing rubber at
the regular intervals between the
cable clamps.
Cable tie
(CV-550B, 2 pcs)
Inside
Cable length
1
2
Note: Hang down the transducer
cables to eliminate the cable
torsion, then measure the cable
length. Make sure that the cables
are not contacted with the
raise/lower shaft when it is
moving.
How to attach the cable fixing plate
Note: The distance between
inside and outside routing
cable must be 30 to 40 mm,
at the location "# (indicated
in the figure above)".
2. WIRING
Outside
2 1
Cable clamp (2 pcs)
Cable fixing rubber (6 pcs)
Cable clamp (2 pcs)
FSV-253-MK2
FSV-254-MK2
1400 mm
1500 mm
1300 mm
1400 mm
Fastening torque:
18.4 N m
Use the hex bolt (M8×16),
spring washer (M8), flat
washer (M8).
2-3