Framing dimensions

H
The main points governing location are flueing and warm air distribution. The Symmetry has an
integrated zero clearance box that isolates the appliance from combustible materials. This means
it can be installed directly into a decorative fireplace constructed from materials such as wood or
plaster.
Corner installations
6 | Symmetry RDV3611 installation guide 11156-H 08-21
W
D
S
Enclosure dimensions
W-width
1100-1125 mm*
850 mm min.
H-height
D-depth
540 mm min.
S - side clearance
* If installing a Symmetry heat transfer kit allow
for an additional 250 mm side clearance per kit.
For example if one kit is being installed the width
would need to be 1350-1375 mm. This additional
clearance is required to ensure the ducting does
not come into contact with the fire.