Page 1
Installation Manual Not intended as a fireplace insert Appliance (including flue) is installed after framing and before cladding. Rinnai strongly recommend appliance is fully tested before any cladding materials are applied. Cladding must be installed up to the flange and not over it. Any overhang will alter the performance of the appliance and cause an unsafe situation.
Fitting the frames and dress guard Commissioning Wiring diagram WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. For assistance or additional information contact Rinnai on 0800 RINNAI (0800 746 624).
Data Plate Centre front of base panel (behind the service panels) Balanced flue: inner = 100 mm, outer = 170 mm Flue Appliance must be installed with a Rinnai supplied flue system Gas Connection ½ “ BSP male flare Gas Type...
A 25 mm clearance is required around the unit (sides and back). Enclosure These are the minimum dimensions required if using the width, height dimensions in a and depth dimensions above. corner Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E 05-10...
9mm Eterpan MD (medium density) is supplied by PBS Ltd (www.pbs.co.nz). Other materials may also be suitable, please seek advice from a cladding supplier as to the correct application and specification of the material. Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E...
(D) of 100 mm will require 350 mm (C) of side clearance. Hearths A hearth is not necessary but can be used for decorative purposes or protection of sensitive flooring if required. It must not obscure the front of the fire. Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E 05-10...
TV, especially if recessed. The Symmetry RDV3610 has fan that distributes warm air from the top of the appliance out into the room. As warm air is dispersed outwards as opposed to directly upwards, installation of a TV may be an option.
Fit cladding, ensuring that non- Fit inner frame, outer frame and mesh combustible cladding is installed above guard (if purchased) the unit (p. 7). Complete commissioning checklist. Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E 05-10...
The electrical cord is not fire rated and should not come into contact with the fire. If the supply cord is damaged, it must be replaced by a licensed tradesperson. This must be a genuine replacement part available from Rinnai, part number 6765B. Rinnai New Zealand Limited...
(framed or frameless). The Symmetry RDV3610 can be installed with the Rinnai granite and metal frames, and also as a frameless installation. The frameless installation can have brick, rock veneer, or tiles, these sit tight up against the framing plate of the fireplace.
Fixing the unit to the frame The Symmetry RDV3610 comes pre-assembled with the burner already in position. For all installations the unit MUST BE positioned on a level surface. 1. Position the unit inside the cavity. 2. Bend and secure the two metal stand-offs supplied with the unit into position. These provide the required 150 mm minimum vertical clearance to the upper lintel.
Flue installation - Rinnai flue kits Rinnai Symmetry RDV3610 flue kits have been based on the flue configurations shown. If you have a combined vertical and horizontal flue configuration you can order separate components to suit. Vertical Flue Horizontal Flue...
Page 14
Flue installation - Rinnai flue kits Symmetry RDV3610 horizontal flue kits and dimensions The following diagram explains the components, dimensions (mm) and appropriate flue kits available for differing horizontal flue installations. Refer to the 'Distance from Appliance to the Cowl' table to calculate what flue pipe length and/or kit you may need.
Flue pipe (length and code) Offset (mm) Rise (mm) None (bend to bend) 150 mm R3630 230 mm R3631 300 mm R3632 450 mm R3633 600 mm R3684 1.2 m R3686 1165 Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E 05-10...
(included with all Rinnai Symmetry flue cowls) and with the Horizontal Flue Flashing Kit instruction sheet. These must be read and modified as necessary with reference to the particular installation The Rinnai Symmetry RDV3610 must be installed with an approved Rinnai flue system.
Page 18
Supporting the flue is usually completed during the framing stage with flue supports or straps within the cavity. Wall straps have been included in the Rinnai Vertical Flue Kit to assist with this. Elbow straps are also available as a separate component to prevent excess weight on the flue elbow.
Restrictor position # 4 1.8 m No restrictor Min. 0.6 m If bend is less than 45 the installation is deemed a vertical termination with 90 bends (refer next page) Max. 1.8 m Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E 05-10...
Page 20
Restrictor position # 2 4.2 m Restrictor position # 3 3.0 m Restrictor position # 4 1.8 m No restrictor Min. 0.6 m after bend Min. 0.6 m Max. 3.5 m Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E 05-10...
Restrictor position # 4 2.4 m No restrictor Example Vertical flue: 2.0 m (2 ÷ 0.692) Max. horizontal flue: 2.9 m Min. 0.6 m Min. 0.3 m Max. 0.9 m Max. 3.5 m Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E 05-10...
To access the gas connection remove the upper and lower bracket (also called the service access panels). The brackets can be removed by undoing the screws Connection Access shown below at each end. Gas Control Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E 05-10...
Before you can install the flue restrictor you need to remove the pilot shield and carefully lift the burner bed out of the unit. Attach the flue restrictor as shown by securing with the screws provided. Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E 05-10...
Handle the log set with care to avoid chipping. It is important you position the pieces in order as shown below as incorrect placement can create carbon build up and affect performance. For video instruction on Rinnai Symmetry log positioning, refer to the following YouTube video: http://www.youtube.com/watch?v=xdxoKomYj9k...
Page 25
Left and Right Middle holes on the burner bed and place the Logs. Ensure the middle elbow section remaining kidney shaped rock on top as rests on the top of the Bottom Log. shown. Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E 05-10...
7. Turn the heater on and off a few times to check ignition. 8. When you are satisfied that the heater is working correctly, reassemble and start the appliance to check the flame pattern (refer next page). Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E 05-10...
Screw into position with the fours screws provided. If you have a granite outer frame, refer to separate installation instructions. Mesh dress guard No fixings required, this inserts flush into the inner frame by hooking onto the top and then pushing in. Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E 05-10...
If operating without a dress guard advise the customer of the safety instructions to prevent the risk of injury. Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E 05-10...
Page 32
Website: www.rinnai.co.nz All Rinnai appliances meet or exceed the safety standards required by New Zealand gas and electrical regulations. Rinnai is constantly improving its products and as such information and specifications are subject to change or variation without notice.