Must be installed by a certified gas fitter in accordance with all applicable local rules and regulations
The Rinnai Symmetry RDV3611 LPG appliance is factory supplied, with rated input of 30MJ/hr for
installation for Horizontal Vent Terminations only. To ensure that optimum Flame Effect and
Maximum Energy Efficiency is obtained when the unit is being installed with a Vertical Vent
Termination the appliance must be up rated to 33MJ/hr by installing this Kit.
Kit Contents
Main Injector
Data Plate
Instruction Sheet
Energy Rating Label (Vertical Flue)
Gas Up Rating Procedure
1. Remove Glass assembly 4 x screws; lift and remove.
2. Remove service panel front 2x screws.
3. Remove service panel rear 2x screws; Lift panel out carefully and put to one side (leaving the
CAT5 cable connected to control panel receiver).
4. Remove log set if installed.
5. Remove burner cover.
Burner assembly
6. Lift the burner assembly out carefully as it is very fragile. NOTE: Extra care should be taken to
avoid scratching the ceramic panels/ combustion chamber walls.
7. Remove and replace the Main Injector with the one supplied.
8. Gently lift the burner assembly back into place. NOTE: Extra care should be taken to avoid
scratching the ceramic panels/ combustion chamber walls.
9. Refit the burner cover.
10. Install the log set.
11. Fit the Field Converted Data Plate next to the existing dataplate to show that it has been field
up rated
12. Commission & set gas pressures for correct gas type as per gas setting procedure.
13. Reassemble the remaining components in reverse order.
Rinnai NZ Ltd
RDV3611 : SYMMETRY
Vertical Flue Up Rating Instructions (ULPG ONLY)
Quantity
Rinnai Part Number
1
1
1
1
Burner Cover
Page 1 of 2
Comments
11534
1.70mm
11152
For Vertical Flues ONLY
11154
Main injector
Pilot head
11154 Issue B