Framing dimensions

The main points governing location are flueing and warm air distribution. The Rinnai Arriva has
an integrated zero clearance box that isolates the appliance from combustible materials. This
means it can be installed directly into a decorative fireplace constructed from materials such as
wood or plaster.
W
H
D
To ensure the appliance performs correctly, without rattling, it must be installed on a flat
level support base that allows free movement of the appliance. The joists used to support the
appliance off the ground must be capable of supporting a minimum of 1.5 times the weight of
the appliance.
Wheels, located at the rear of the heater, allow the unit to slide in and out of the enclosure for
installation and maintenance.
Installer please note:
Issues caused by 'rattling' fires not installed on a flat level base, as detailed in these
instructions, will not be covered by warranty.
Left and right wheels
Joist
Plywood board, minimum 18 mm
720 mm
W-width
850-860 mm
H-height
660-665 mm
D-depth*
380 mm direct flue
475 mm extended flue
500 mm underfloor flue
Dimensions provided are critical to the
installation and must be adhered to.
* Depth dimensions vary depending on the
flue installed, refer p. 9 for further detail.