4.3 Protective elements
In range of mechanical, electric, and hygienic protection the device described in thos
manual conforms to the following standards:
MECHANICAL PROTECTION: 2006/42.
ELECTRIC PROTECTION: 2006/95/CEE; 2004/108/CEE.
HYGIENIC PROTECTION: Reg. 1935/2004.
The vegetable cutter GMS600 has electronic and mechanic protective devices
conforming to the standard requirements, either during operation and cleaning and
maintenance.
Nevertheless there are RESIDUAL RISKS impossible to exclude in 100%, indicated in
this manual with the following expression: WARNING!
Those risks are connected with injury hazard during operation, replacement, and/or
cleaning of cutting disks.
WARNING!
Never remove safety, operational, and warning labels from the vegetable cutter,
keep them in readable condition.
Electric protective elements
The vegetable cutter GMS600 is equipped with the following sensors:
A
on the pusher lever,
it is designed for stopping the device when the pusher lever is lifted above the lid
hole and allows for automatic restart after return to normal conditions (fig. 2).
When the pusher lever
is lowered
- 40 -
Lifted pusher lever
(above the lid hole)
Sensor
Fig. 2