Power Supply
Mains supply: 230 / 12 V; 0.5 A adapter
DC power supply: 10 to 16 V DC
12V consumption:
Standby 90 mA 
Call – typ. 300 mA, max. 600 mA
Data – typ. 200 mA, max. 400 mA
Battery charge – additional consumption 70 mA (Battery backup version only)
Supply connector: DC Jack 5.5/2.1 mm, positive to center
When other power source than supplied adapter is used, the power source must meet
the criteria for SELV standard.
Battery backup (optional)
Accumulator type: Charging cell NiMh size AA
Number of pieces: 4
Power consumption from batteries:
Standby – typ. 230 mA 
Call – typ. 600 mA, max. 1200 mA
Data – typ. 350 mA, max. 800 mA
Charging current: Typ.70 mA, regulated
Accumulators are not part of delivery.
Telephone interface
Interface type: 2-wire analog, FXS
Telephone connector type: RJ-12, 6/2
Call impedance: 600 Ω
Loop voltage: 48 V DC
Loop current: max. 40 mA
Loop resistance: max. 800 Ω
Tone frequency: adjustable, default 425 Hz
Dialing type: tone (DTMF) and pulse
Ringing voltage: 42 Vrms 50/25 Hz
Calling line identification: CLI during ringing according to ETSI FSK
Tariff pulses: f=16/12 kHz ; Umin=100mVef on 200 Ω
Answer supervision: polarity reversal, 12/16 kHz pulses