Power Supply
•
Mains supply: 230 / 12 V; 0.5 A adapter
•
DC power supply: 10 to 16 V DC
•
12V consumption:
•
Standby 90 mA
•
Call – typ. 300 mA, max. 600 mA
•
Data – typ. 200 mA, max. 400 mA
•
Battery charge – additional consumption 70 mA (Battery backup version only)
•
Supply connector: DC Jack 5.5/2.1 mm, positive to center
•
When other power source than supplied adapter is used, the power source must meet
the criteria for SELV standard.
Battery backup (optional)
•
Accumulator type: Charging cell NiMh size AA
•
Number of pieces: 4
•
Power consumption from batteries:
•
Standby – typ. 230 mA
•
Call – typ. 600 mA, max. 1200 mA
•
Data – typ. 350 mA, max. 800 mA
•
Charging current: Typ.70 mA, regulated
•
Accumulators are not part of delivery.
Telephone interface
•
Interface type: 2-wire analog, FXS
•
Telephone connector type: RJ-12, 6/2
•
Call impedance: 600 Ω
•
Loop voltage: 48 V DC
•
Loop current: max. 40 mA
•
Loop resistance: max. 800 Ω
•
Tone frequency: adjustable, default 425 Hz
•
Dialing type: tone (DTMF) and pulse
•
Ringing voltage: 42 Vrms 50/25 Hz
•
Calling line identification: CLI during ringing according to ETSI FSK
•
Tariff pulses: f=16/12 kHz ; Umin=100mVef on 200 Ω
•
Answer supervision: polarity reversal, 12/16 kHz pulses
User Guide 2N® EasyGate PRO
80 / 87