Number length (Function No. 393)
The parameter defines the expected length of a number with a prefix included on the same row.
This enables you to start dialing into a GSM network immediately after the last digit is dialed. If
the phone number to be dialed is shorter, the timeout is respected. The "0" setting means that
the function is disabled.
Setting options: 0, 3 –15
Setting step: 1
Default setting: 0
 
End with # (Function No. 394)
This parameter enables you to establish a call when a # is received. The # character is removed
from the dialed number. Should a # be part of the dialed number, this function cannot be used
for the given prefix.
Setting options: YES (1) / NO (0)
Default setting: NO
 
Remove (Function No. 395)
The Remove parameter is used for automatic call routing. A defined count of digits (prefix) is
removed from the number beginning.
Setting options: 0–20
Setting step: 1
Default setting: 0
 
Add (Function No. 396)
The Add parameter is used for automatic call routing. A defined string (prefix) is added to the
beginning of the number to be dialed.
Setting options: 0–8 characters (0–9, *, #, +)
Default setting: blank
 
Extra tariff (Function No. 397)
Pseudo tariff metering setting (tariff is based on call duration). The Extra tariff parameter defines
transmitting of a fixed quantity of tariff pulses after the call start. This parameter sets the
minimum call cost.