We support only standard SMS, it means 7-bit SMS max 160 characters, 8-bit SMS max 140
characters.
Responses:
L1 CNF OK
L1 DEF OK
L1 SET OK
L1 RST OK
L1 ERR Invalid Message In front of SMS wasn't L1
L1 ERR Unknown Command Different command tham CNF, DEF, SET or RST
L1 ERR Invalid Password Wrong password
L1 ERR Invalid Parameters Wrong parameters of commands CNF a SET.
L1 ERR Invalid Syntax Error in spaces, equal signs, wrong characters etc.
L1 ERR Does not Respond Lift1 doesn't hook off either after 60s of ringing Lift1 hooks off, doesn't
accept command to CPC programming Lift1 hooks on during programming Lift1 dosnt respond
to communication commands (WRITE_START, WRITE_CONFIRM, CRC_REQUEST)
Error signalization
Special version of EasyGate is able to signalize following errors:
- Battery error signalization (interrupted, short circuit, time to replace)
- Network error signalization (lost signal)
Signalization methods:
- Lift1/P100* - only battery error signalization (without connection no way to send
information)
- FXS line voltage break - interrupted supplying on FXS port
- Relay signalization - connected relay contact signalize error
*Sending information to call center by protocol P100, only when communicator Lift1 is used
together with EasyGate , this communicator must be set to use P100 signaling. Direct
communication P100 from EasyGate is not implemented, although the parameters can be set in
the programming tool.
Vizual signalization
Special version of EasyGate signalize by LED following information:
- Technology of connection - LTE version only - you can easily recognize, if the module is
connected by LTE, WCDMA or GSM technology by LED's, which show signal strength. LED's
User Guide 2N® EasyGate PRO