2N EasyGate PRO User Manual page 51

Hide thumbs Also See for EasyGate PRO:
Table of Contents

Advertisement

Power error -FXS Line voltage break when main power is disconnected and battery is flat, or
battery failure
Network or battery error -both states are signalized by FXS line voltage break.
Default setting: Off
Relay signalization Function No.: 969
You can set signalization of network registration and powering state by NO relay contact.
Contact is closed all time when selected problem lasts.
Setting options: Off -Contact is open all the time
Network error - Contact is closed when not registered to network
Power error - Contact is closed when main power is disconnected or battery is low, or battery
failure
Network or battery error - both states are signalized by closed contact.
Default setting: Off
Id text Function No.: 968
Fill in Identification text for Checking SMS. It will be place on SMS beginning. If text is blank,
P100 Id number is used, if the P100 Id is empty, Serial Number is used. When the parameter is
programmed by SMS, the text must be in brackets () and no brackets used inside of the text.
Setting options: 0-40 characters
Default setting: blank
ID number Function No.: 971
Fill in Identification code for P100 protocol.
Setting options: 0-16 characters (0-9)
Default setting: blank
P100 phone number Function No.: 972
Not implemented in EasyGate!
Fill in phone number of your monitoring center. This number will be dialed in case of P100 call.
Setting options: 0-16 characters (0-9)
Default setting: blank