SIM2:2302;Home;3G;-77dBm Dual SIM version only
Power:On Line power
Battery:Ok Battery status
Expire in:730 Time to battery change (days)
To use this function, following parameters must be set:
Checking SMS: 967
Id text: 968
Battery status SMS: 962
Power failure SMS: 963
Telephone number for service SMS: 714
SMS EasyGate programming
Special versions of EasyGate have the possibility to program parameters using SMS. When is this
service allowed, the SMS receiving thru serial port is blocked. This option is available with
special firmware only, information about types supporting this option are supplied by the
producer.
When you program any parameter which consists of string, the text must be in brackets () and no
brackets are allowed inside of the text.
Following operations can be performed using SMS. For every operation separated SMS is
needed.
1. Configuration
Parameter value change (see the table of parameters below). As the separation character is
used space. When the text is set, it must be closed in brackets. More parameters can be set
in one SMS, the maximal length of SMS is 160 characters for 7-bit SMS, 140 characters for 8-
bit SMS. When the setting out of permitted limits is demanded or other error occur, none of
parameters is changed.
SMS syntax: EG CNF password parameter_number=new_value
Example: EG CNF 12345 101=10 706=(internet.t-mobile.cz)
EG CNF – declaration that this is configuration SMS for EG
12345 – password for programming, here is default value
101=10 – time to dial is set to 10 s
706=(internet.t-mobile.cz) – APN setting to T-Mobile CZ
2. Default setting
Restore default setting of EasyGate. After this operation automatic restart follows.