SMS Syntax: EG DEF password
Example: EG DEF 12345
12345 – password for programming, here is default value
3. Restart
SMS Syntax: EG RST password
Example: EG RST 12345
12345 – password for programming, here is default value
The answer to the SMS:
EG.CNF OK Correct setting
EG.DEF OK Default values restored
EG.RST OK Correct restart
EG.ERR Invalid Message Keyword EG missing
EG.ERR Unknown Command Different command than CNF, DEF, RST
EG.ERR Invalid Password Invalid Password
EG.ERR Invalid Parameters Invalid parameter in CNF command
EG.ERR Invalid Syntax Error in spaces or other syntax
Programming Lift1 communicator using EasyGate
Special version of EasyGate allows to program connected communicator Lift1 using SMS.
EasyGate receives SMS with demand to program Lift1. EasyGate than establishes connection to
L1 by phone line and performs programming using CPC protocol.
Supports 4 types of SMS commands
1. Config
SMS syntax: L1 CNF keyword parameter1=value parameter2=value Following example
programs call numbers -. parameters 011 and 012: L1 CNF 12345 011=00420222222222
012=00420111111111
2. Default config setting
SMS syntax: L1 DEF keyword
3. Selection of profile n (when you select profile 1, the same as previous command) SMS
syntax: L1 SET keyword n
4. Restart
SMS syntax: L1 RST keyword
It is not possible to combine more commands in one SMS.