Fault code No.
Item
3-3
[For P1604] Ground short circuit
Between lean angle sensor coupler and ground: yellow/green–ground
If there is continuity, replace the wire harness.
3-4
[For P1605] Open circuit
Between lean angle sensor coupler and ECU coupler: blue–blue
If there is no continuity, replace the wire harness.
3-5
[For P1605] Open circuit
Between lean angle sensor coupler and ECU coupler: yellow/green–yellow/green
If there is no continuity, replace the wire harness.
P1604, P1605
[P1604] Lean angle sensor: ground short circuit detected.
[P1605] Lean angle sensor: open or power short circuit detected.