Fault code No.
Item
3-3
[For P0112] Ground short circuit
Between throttle body sensor assembly coupler and ground: brown/white–ground
If there is continuity, replace the wire harness.
3-4
[For P0113] Open circuit
Between throttle body sensor assembly coupler and ECU coupler: brown/white–brown/white
If there is no continuity, replace the wire harness.
3-5
[For P0113] Open circuit
Between throttle body sensor assembly coupler and ECU coupler: black/blue–black/blue
If there is no continuity, replace the wire harness.
3-6
Disconnect the couplers from the parts that are connected to the ECU.
Refer to "Parts connected to the ECU" on page 8-35.
P0112, P0113
No normal signals are received from the intake air temperature sen-
sor.
[P0112] Intake air temperature sensor: ground short circuit detected.
[P0113] Intake air temperature sensor: open or power short circuit
detected.
B/L Y L P/W Br/W
G/Y
P
B/L Y L P/W Br/W
Sb
Gy
L/B
G/Y
P
B/L Y L P/W Br/W
Sb
Gy
L/B
8-42
FUEL INJECTION SYSTEM
L
L
R/W W Br/R B/L
O/B
B/L Y/B
B/W
L/Y
G/R
Y Y/G
L/R
B/L
W/Y
Br/W Gy/R R/B B/L
W/R B W/B O
Y/L B/W
P/W
L
L
R/W W Br/R B/L
O/B
B/L Y/B
B/W
L/Y
G/R
Y Y/G
L/R
B/L
W/Y
Y/L B/W
P/W
Br/W Gy/R R/B B/L
W/R B W/B O