Electrical Connections; Figure 6 Electrical Connection And Main Switch ① - M&C PSS Series Instruction Manual

Portable gas conditioning unit
Hide thumbs Also See for PSS Series:
Table of Contents

Advertisement

11.2

ELECTRICAL CONNECTIONS

Warning
Note
The PSS-20 gas conditioning systems are available with either 230 V/50 Hz or with 115 V/60 Hz (for
circuit diagram see appendix). A 4 A fuse is used on all models as fuse protection. The fuse is located
on the clamp mounting rail (see Figure 2). When optionally using a temperature controller with heated
gas sample line, the overload protection increases to 10 A.
The electrical connection is made via a cold appliance plug with 2 m cable on the left side of the case.
The power socket is equipped with a two-pole main switch.
Figure 6
Electrical connection and main switch
20
False supply voltage can damage the equipment. When connecting the
equipment, please ensure that the supply voltage is identical with the
information provided on the model type plate!
For the erection of power installations with rated voltages up to 1000 V,
the requirements of VDE 0100 and relevant standards and
specifications must be observed!
The main circuit is equipped with a fuse corresponding to the nominal
current (over current protection); for electrical details see technical
data.
PSS-20 | 1.00.01
www.mc-techgroup.com