Option " heated sample line":
For the electrical supply of a heated sample line with PT-100 sensor and/or the connection of other
heated components, e.g. heated sample gas probe or heated filter, a connection socket as shown in
Figure 7 is available. The maximum connected load is 6 A, 1380 W for the 230 V sample gas conditioning
or 6 A, 690 W for the 115 V version.
The maximum length of the usable heated sample line is calculated as follows:
Max. connected load [W] - Power consumption of heated components (e.g. sample probe) [W]
L(m)=
Power consumption heated line per meter [W/m]
Be wired with the temperature controller according to the pin connection plan (see figure 7). This
enables you to make a simple, easy servicing connection between the heated sample lines 3/4/5-
N/M/H or PSP4M (-W) by means of the multipolar coupler plug (standard equipment of the heated
sample lines) with the temperature controller.
Figure 7
Circuit diagram of the 7-pin socket