Venting Options - ElectrIQ eiQCHFGBSS60 User Manual

Angled glass and steel designer chimney cooker hood
Table of Contents

Advertisement

EXTERNAL VENTING
If you have an outlet to the outside, your cooker hood can be
connected as shown in the diagram using any suitable
extraction duct (enamel, aluminium, flexible pipe or
inflammable material with an interior diameter of 150mm) can
be used.
An adaptor is supplied to enable you to connect your hood to
pre-existing 120mm diameter ducting.
If this is the chosen installation method consideration to the
route of the vent pipe should be made prior to installation.
RECIRCULATION
This cooker hood also supports the recirculation of air once it has passed
through the filters. The filtered air is then expelled through the
vent holes in the side of the chimney.
When setting the unit up in this configuration, carbon filters
should also be used to remove odours from the air. Details of
sourcing and fitting the filters can be found in the Carbon filter
section.
When setting up for recirculation the installation instructions
should be followed, but a vent pipe should not be attached, and instead the air
can be routed back into the room through the top of the unit.