OPTIONS FOR VENTILATION

This hood can be set up for either external venting or recirculation of the air. The type of setup should
be decided before commencing installation.
INSTALLATION
If you have an outlet to the outside, your cooker hood can be connected as below picture by means of
an extraction duct (enamel, aluminum, flexible pipe or non-flammable material with an interior diameter
of 150mm)
1. Before installation, turn the unit off and unplug it from the outlet.
2. The cooker hood should be placed at a distance of 65~75cm above the cooking plane for best
effect.
3. Install the hook on a suitable place once the installation height is fixed, and keep it in line. The fixed
position of the inside chimney bracket is the highest place of chimney. See pic 2.