Abz-Phase Differential Output Load Side Encoder - Mitsubishi Electric MELSERVO-J3 Series Instruction Manual

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

3. LOAD SIDE ENCODER

3.3 ABZ-phase differential output load side encoder

This section describes the connecti on of the ABZ-phase differential output load side encoder. Prepare the MR-
J3CN2 connector set for the load side encoder cable and produce it according to the wiring diagram in (3) in
this section.
(1) ABZ-phase differential output load side encoder specifications
Each signal of the A, B and Z-phase of the load side encoder is provided in the differential line driver output.
It cannot be provided in the collector output.
The phase differences of the A- and B-phase pulses and the pulse width of the Z-phase pulse need to be
200ns or more.
The load side encoder without the Z-phase cannot make a home position return.
Load side encoder
Equivalent to
AM26LS31
(2) Connection of servo amplifier and ABZ-phase differential output load side encoder
Servo amplifier
CN2L
LA
LAR
LA, LB, LZ
LB
LAR, LBR, LZR
LBR
LZ
LZR
Connector set
MR- J3SCNS (option)
Phase difference: 200ns or more
1 pulse of Z-phase = 200ns or more
ABZ-phase differential output load
side encoder
Linear encoder
or
Rotary encoder
3 - 14