Input / Output Specifications; Environmental Specifications; Set Item List - Mitsubishi Electric LE-50PAU Instruction Manual

Power amplifier/tension controller
Table of Contents

Advertisement

3.2 Input / output specifications

Terminal
Item
name
L
Power
N
supply
SET
SN
PP
PN
Input
S1
signal
S2
SP
ST
Output
RC
signal
SC
SN

3.3 Environmental specifications

Ambient temperature
Ambient humidity
Vibration resistance
Impact resistance
Noise resistance
withstand voltage
Insulation resistance
Grounding
Operation atmosphere • Free from corrosive or flammable gas and conductive dust, less dust.

3.4 Set item list

Input signal voltage revel
Stop timer
Stop gain
Stop bias
Aux.power output timer
Non-linearity compensasion
• 100 to 240 VAC (-15% to +10%) , 50/60 Hz
• Power consumption: 400 VA (at 24 VDC, 4A)
• Allowable instantaneous power interruption: 10 ms
• Service power supply for the external variable resistor
• 8VDC. External variable resistor : 2kΩ
• Power amplifire output
• 0 to 24 VDC, 4 A or less
[1] Aux.power output : 10VDC 2A
Load resistance :4.8Ω / 75ºC or over
[2] RUN (normal operation) output
DC12V 100mA
• Control signal
Internal resisitance : 22kW
Signal level is set using DIP switch and key.
• Start signal
When input is turned off, stop gain, stop bias and stop timer are
valid.
• Output remote signal
ON : power amplifier output ON
OFF : power amplifier output OFF
• Aux.power output ON/OFF signal
ON : Aux.power output ON
OFF : Aux.power output OFF
• Input signal common terminal
• 0 to 55ºC- - - - during operation
• 35 to 85% RH (no condensation)during operation
• 10 to 55Hz 0.5mm (19.6m/s
2
• 98m/s
3 times in each axis direction.
• By noise simulator with 1,000Vp-p noise voltage, 1µs noise width and 30 to 100Hz.
• 1,500V AC, 1 minute
• 5MΩ or more by 500V DC megger
• Class D grounding. ( 100Ω or less. Grounding shall not be performed together with
any high power system.)
Symbol
Unit
Vmax
V
SPT
s
SPG
%
SPB
%
SST
s
T10,T20,
%
T40,T80
10
Specifications
• Power fuse : 250 V, 8 A ×2, built in
• Rush current : 50A, 300ms
• Load resistance :4.8Ω / 75ºC or over
ON/OFF mode
: Logic invrsion ready
2
max) 2 hours in each axis direction.
Between power terminal and earth treminal
Range of setting
Minimum Maximum
0.5 ~ 8V
0
30
0
300
0
60
0
30
1.0
99.0
Set output
mode by set-
ting operation
Input current
DC12V 5mA
Initial value
5.0
10
100
0
10
10, 20,
40, 80

Advertisement

Table of Contents
loading

This manual is also suitable for:

Le-50pau-set

Table of Contents