GENERAL INFORMATION
Fig. 2-8 Automatic Datalogging Enabled
During automatic datalogging the instrument stores the
values of all gas ranges together with the current time and
date at 60 second intervals.

Manual Datalogging

By default, the instrument has manual datalogging enabled
in all modes (CGI, CSM, PURGE and TRAC).
The user can initiate a manual log with a double press of
(Button 3), if the pump is running.

Construction

The instrument is housed in a tough, impact resistant,
moulded case made of polypropylene.
The top panel is protected by a stainless steel top plate
covering a toughened glass LCD cover.
The battery cover is attached to the main instrument body
by means of two stainless steel hexagonal screws.
The instrument is sealed against dust and water to IP54
standard. The instrument sensors are protected from dust
and water by membrane and cotton filters, when using
probe handle assembly (Part No. 12481). Other probes with
associated filters are available as accessories.
2-9