9.2. Technical Data Probe
9.2.1. Mechanical Data Probe
Mechanical Data Probe
Upper housing material
Bottom housing material
Material measuring tip
Dimensions (length / diameter)
Weight
Robustness/ ambient conditions
IP-rating
Operating temperature
Storage temperature
Max. surface temperature in continuous
measurement mode
Max. surface temperature at 1s test time ever 20s
9.2.2. Electrical Data Probe
The probes may only be used with the gauges QNix® 9500 and QNix® 5500.
Stainless steel (1.4305)
Trogamid® (CX7323)
Polished ruby (Al
O
)
2
3
35,5 mm / 14,5 mm
11,9 g
IP65 (closed)
-20 °C to +70 °C
-20 °C to +70 °C
80 °C
100° C