  • Page 1 opERATIoN Mode d‘emploi Guía rápida Handleiding Instrukcja obsługi MANUAL Istruzioni QNix 9500 ® QUALITY „MADE IN GERMANY“...
  • Page 2 9500 Contents English ............................Guía rápida Español ........................Mode d'emploi abrégé Français ....................Brevi istruzioni Italiano ....................... Korte handleiding Nederlands ....................Skrócona instrukcja obsługi Polski ..................... QNix 9500 EN_ES_FR_IT_NL_PL 3 / 48...
  • Page 3: Table Of Contents

    9500 9500 Table of Contents Table of Contents Editing Areas ........................25 Table of Contents 4.7.1 Configuring areas ......................25 General Information ........................ 7 4.7.2 Add area during measurement ..................25 Intended Use ........................7 4.7.3 Enable / Disable Area ..................... 26 Scope of Delivery ........................
  • Page 4 9500 9500 Table of Contents 1 General Information 9500 Probe Technical Data ......................36 1 General Information 1 General Information 9.2.1 Probe mechanical data....................36 These operating instructions describe the gauges QNix® 9500B (Basic) QNix® 9500P (Premium) and 1 General Information 9.2.2 Probe Electrical Data .......................
  • Page 5 9500 9500 1 General Information 2 Device Overview 2 Device Overview CAUTION Electromagnetic compatibility Electromagnetic influences in the surrounding area may interfere with the device resulting in false readings. Only use probe cables and USB cables under 3 m in length to connect the device. Do not operate the device with an external USB power supply.
  • Page 6 9500 9500 2 Device Overview 2 Device Overview 2.1 Menu Overview 2.1.1 "Jobs" Menu Use the buttons to navigate within the four main menus (Jobs, Limits, Calibration and Set- tings). Navigating within the menus: Symbol / button Explanation Previous / next menu; when entering values: previous / next decimal place Previous / next menu item;...
  • Page 7 9500 9500 2 Device Overview 2 Device Overview 2.1.2 "Limits" Menu 2.1.3 "Calibration" Menu Illustration 3: Calibration menu structure Model 9500P+ has calibration methods based on relevant standards preallocated. Use menu item "Custom" or the software QN9 to customise the calibration. Illustration 2: Limits menu structure 12 / 48 QNix 9500 EN_ES_FR_IT_NL_PL...
  • Page 8 9500 9500 2 Device Overview 3 Initial Operation 3 Initial Operation 2.1.4 "Settings" Menu 3.1 Insert Battery This device includes: > Type mignon/AA (LR6 / FR 6 / AM3); quantity 2 > Type button cell CR-1220 (backup battery for system clock); quantity 1 The battery compartment is located at the back of the device.
  • Page 9 9500 9500 3 Initial Operation 4 Operation and Controls Remove the probe holder or probe cable from the probe input 3.4 Software Backup > To unlock, turn the probe input anti-clockwise. The arrow on the probe holder shows the open The "QN9"...
  • Page 10 9500 9500 4 Operation and Controls 4 Operation and Controls NOTICE Measurement results Available options Unit ® ® ® QNix 9500B QNix 9500P QNix 9500P+ During calibration use the uncoated original substrate for the most accurate measurements. Settings Zeroing NOTICE Error of measurement 1-point Rough surfaces or dirt can cause errors of measurement.
  • Page 11 9500 9500 4 Operation and Controls 4 Operation and Controls 4.3 Measurement Display Section Symbols Description The measurement display contains the areas Current measurement (within the limits) Not all measurements for averaging have been recorded Measurement outside the limits n-1: Last and next to last measurement n-2: NFe / Fe...
  • Page 12 9500 9500 4 Operation and Controls 4 Operation and Controls 4.3.1 Focus Frame You can already navigate through measurements whilst the test is running to analyse these or erase individual values. To do so, open the focus frame with the buttons and navigate to the desired area.
  • Page 13: Editing Areas

    9500 9500 4 Operation and Controls 4 Operation and Controls Erase all measurements in an area: 4.7 Editing Areas > Open the "Jobs" menu. 4.7.1 Configuring areas The current job is highlighted. With models QNix® 9500P and 9500P+ you can configure several areas for one job (see chart in >...
  • Page 14: Enable / Disable Area

    9500 9500 4 Operation and Controls 4 Operation and Controls Enabled area 4.8 Configure Limits The number of the enabled area will appear in the "Jobs / Area" bar in the measurement display. You can change the limit parameters in the "Limits" menu. You can configure a different limit set for When adding an area, the number will automatically increase.
  • Page 15: Select Language

    9500 9500 5 System Settings 5 System Settings The probe has a colour indicator to show when the set limits have been exceeded. NOTICE > Green: measurement within the limits The preset rotation does not change the function of the buttons (0°, 90°, 180° and 270°). Rotation >...
  • Page 16: Set Pin

    9500 9500 5 System Settings 6 Device Management via PC in QN9 6 Device Management via PC in QN9 5.6 Set PIN You can add a 4-digit PIN to lock certain device functions. You can use the QN9 software to manage your devices on a PC. Among other things, you will be able >...
  • Page 17: Install App

    9500 9500 6 Device Management via PC in QN9 6 Device Management via PC in QN9 6.2 Manage Jobs Index Software menu Function You can easily prepare jobs on the PC and then transfer them to the hand-held unit. The software 4, 5 Help/support Instructions...
  • Page 18: Troubleshooting

    If you have any questions, please contact your local retailer or our Support: www.q-nix.com/support Illustration 7: Select the job you want to export. Automation Dr. Nix GmbH & Co KG > Select the desired template from "REPORT TEMPLATES" Robert-Perthel-Strasse 2 >...
  • Page 19: Appendix

    9500 9500 9 Appendix 9 Appendix 9 Appendix Robustness / ambient conditions 9.1 Gauge Technical Data IP rating IP65 (closed) Operating temperature -20 °C to +70 °C 9.1.1 Gauge Mechanical Data Storage temperature -20 °C to +70 °C Mechanical Data Max.
  • Page 20 9500 9500 9 Appendix Guía rápida / 1 Avisos generales 9500 Measuring Data Guía rápida / 1 Avisos generales 1 Avisos generales Minimum curvature radius, convex (accuracy tested up to 250 µm) 1.1 Uso adecuado 1 Avisos generales Zeroing and 4 mm 30 mm Según su variante, este dispositivo se emplea para medir el espesor del recubrimiento de una super-...
  • Page 21 1.1 Utilisation conforme lique. Pour les supports en acier ou en fer (sonde FE), l'épaisseur peut être déterminée à partir de Automation Dr. Nix GmbH & Co KG revêtements non conducteurs (par ex. peinture, émail) comme de revêtements conducteurs mais L'appareil est utilisé...
  • Page 22 (ad es. vernici, smalti) e di rivestimenti conduttivi ma non magnetici (ad A seconda della variante l'apparecchiatura serve alla misurazione dello spessore di rivestimenti su Automation Dr. Nix GmbH & Co KG es. cromo, rame, zinco). Su fondi metallici non magnetici (ad es. alluminio, rame, ottone), con una un fondo metallico.
  • Page 23 (bijv. lak, emaille) alsook van geleidende, maar niet-magnetische coatings (bijv. Het apparaat dient afhankelijk van de variant voor het meten van de laagdikte van coatings op een Automation Dr. Nix GmbH & Co KG chroom, koper, zink) worden bepaald. Op niet-magnetische metalen ondergronden (bijv. aluminium, metalen ondergrond.
  • Page 24 (np. lakiery, emalie), jak i na powłokach prze- Urządzenie w zależności od wersji służy do pomiaru grubości warstwy powłok na podłożu me- Automation Dr. Nix GmbH & Co KG wodzących, ale niemagnetycznych (np. chrom, miedź, cynk). Na niemagnetycznych podłożach me- talicznym.
  • Page 25 QNix® 9500P+(Premium+) producenta. W razie pytań prosimy zwrócić się do swojego dystrybutora na miejscu lub do naszego działu obsługi klienta: www.q-nix.com/support Automation Dr. Nix GmbH & Co KG Robert-Perthel-Strasse 2 50739 Köln Niemcy Tel.: +49 (0)221 91 74 55-0 Faks: +49 (0)221 17 12 21 info@automation.de...
  • Page 26 9500 CAUTION NOTICE NOTICE 8 / 48 QNix 9500 EN_ES_FR_IT_KR_NL_PL...
  • Page 27 V2.0 • 2-2020 Automation Dr. Nix GmbH & Co. KG Robert-Perthel-Str. 2 50739 Köln – Germany Tel. +49 (0) 221 91 74 55-0 Fax +49 (0) 221 17 12 21 info@automation.de www.q-nix.com...