GDC Espedeo Supra Supra-5000 User Manual page 186

Digital cinema and secured media projection system
Table of Contents

Advertisement

Lens
32003
Communication failure.
Driver
Lens
33001
Lens data uninitialized.
Driver
The voltage is lower than 10.5
56001
LDM
56002
LDM
The voltage is lower than 10 V.
The voltage is higher than 13.5
56003
LDM
The voltage is higher than 14
56004
LDM
The voltage is lower than 4.5
57001
PIB
The voltage is lower than 4.4
57002
PIB
The voltage is higher than 5.5
57003
PIB
The voltage is higher than 5.6
57004
PIB
The voltage is lower than
58001
PIB
The voltage is lower than 3.0
58002
PIB
The voltage is higher than
58003
PIB
The voltage is higher than 3.6
58004
PIB
71101
DCMB
Heartbeat packet lost.
Heartbeat packet lost for a
71102
DCMB
Supra-5000 Digital Cinema and Secured Media Projection System
User Manual
1. The lens driver board is damaged.
2. The connection cable falls off or is
damaged.
No lens data is found.
1. The 12 V tributary of the power
module is faulty.
V.
2. The 12 V load of the power
module is faulty.
1. The 12 V tributary of the power
module is faulty.
2. The 12 V load of the power
module is faulty.
The 12 V tributary of the power
V.
module is faulty.
The 12 V tributary of the power
V.
module is faulty.
The 5 V tributary of the PIB board is
V.
faulty.
The 5 V tributary of the PIB board is
V.
faulty.
The 5 V tributary of the PIB board is
V.
faulty.
The 5 V tributary of the PIB board is
V.
faulty.
The 3.3 V tributary of the PIB board
3.135 V.
is faulty.
The 3.3 V tributary of the PIB board
V.
is faulty.
The 3.3 V tributary of the PIB board
3.465 V.
is faulty.
The 3.3 V tributary of the PIB board
V.
is faulty.
1. The DCMB board is not started.
2. The DCMB board is faulty.
1. The DCMB board is not started.
long period.
2. The DCMB board is faulty.
1. Check whether the control cable of the lens drive
board (identified as Lens Ctrl) is loose and whether the
connection position is correct.
2. Replace the lens driver board with a new one.
Log in to the UI as the administrator. Choose
Administrator Settings > Select Lens and select the
correct lens type.
1. Replace the power module.
2. Disconnect the 12 V load of the power module (DCMB,
PIB, TEC driver board, etc.) and check whether the 12 V
power supply resumes being normal. If yes, then the 12
V load is faulty. In this case, check and identify other
faulty loads.
If not, then replace the power module.
1. Replace the power module.
2. Disconnect the 12 V load of the power module (DCMB,
PIB, TEC driver board, etc.) and check whether the 12 V
power supply resumes being normal. If yes, then the 12
V load is faulty. In this case, check and identify other
faulty loads.
If not, then replace the power module.
Replace the power module.
Replace the power module.
Replace the PIB board.
Replace the PIB board.
Replace the PIB board.
Replace the PIB board.
Replace the PIB board.
Replace the PIB board.
Replace the PIB board.
Replace the PIB board.
1. Wait patiently for the DCMB board to fully start.
2. Try to replace and check the DCMB board. If the fault
phenomenon occurs with only the DCMB board, replace
the DCMB board.
1. Wait patiently for the DCMB board to fully start.
2. Try to replace and check the DCMB board. If the fault
phenomenon occurs with only the DCMB board, replace
the DCMB board.