GDC Espedeo Supra Supra-5000 User Manual page 173

Digital cinema and secured media projection system
Table of Contents

Advertisement

Light
The phosphor motor
20015
Source
temperature_High
Light
The phosphor motor
20016
Source
temperature_Too high
Light
The phosphor motor
20017
Source
drive_Startup failure
21001
Projector
FAN1 rotation speed_Low.
21002
Projector
FAN1 rotation speed_High.
21003
Projector
FAN2 rotation speed_Low.
21004
Projector
FAN2 rotation speed_High.
Supra-5000 Digital Cinema and Secured Media Projection System
User Manual
1. The projection room temperature
is higher than 35℃.
2. The air inlet or air outlet of the
projector is blocked.
3. The filter of the projector is
clogged.
1. The projection room temperature
is much higher than 35℃.
2. The air inlet or air outlet of the
projector is blocked.
3. The filter of the projector is
clogged.
4. The system fan is faulty.
The PIB laser control module is
abnormal or suspended.
1. The fan power cable is damaged.
2. The fan is blocked.
3. The fan drive on the PIB board is
faulty.
4. The fan extension cable is faulty.
5. The service life of the fan has
ended.
1. The fan power cable is damaged.
2. The fan is blocked.
3. The fan drive on the PIB board is
faulty.
4. The fan extension cable is faulty.
5. The service life of the fan has
ended.
1. The fan power cable is damaged.
2. The fan is blocked.
3. The fan drive on the PIB board is
faulty.
4. The fan extension cable is faulty.
5. The service life of the fan has
ended.
1. The fan power cable is damaged.
2. The fan is blocked.
3. The fan drive on the PIB board is
faulty.
4. The fan extension cable is faulty.
5. The service life of the fan has
ended.
- 173 -
1. Check the projection room temperature.
2. Check whether there are obstacles at the air inlet
or air outlet.
3. Check and replace the air inlet filter.
1. Check the projection room temperature.
2. Check whether there are obstacles at the air inlet
or air outlet.
3. Check and replace the air inlet filter.
4. Check and replace the faulty system fan.
Reset the PIB laser control module or restart the
whole machine.
1. Check whether the fan power cable is damaged. If
yes, repair or replace the fan.
2. Check whether the fan is blocked. Ensure that the fan
can rotate freely.
3. Locate the problem with other fans. If the fault
phenomenon occurs only with the current fan, replace
the fan. If not, replace the PIB board.
4. Replace the fan extension cable.
5. Replace the fan.
1. Check whether the fan power cable is damaged. If
yes, repair or replace the fan.
2. Check whether the fan is blocked. Ensure that the fan
can rotate freely.
3. Locate the problem with other fans. If the fault
phenomenon occurs only with the current fan, replace
the fan. If not, replace the PIB board.
4. Replace the fan extension cable.
5. Replace the fan.
1. Check whether the fan power cable is damaged. If
yes, repair or replace the fan.
2. Check whether the fan is blocked. Ensure that the fan
can rotate freely.
3. Locate the problem with other fans. If the fault
phenomenon occurs only with the current fan, replace
the fan. If not, replace the PIB board.
4. Replace the fan extension cable.
5. Replace the fan.
1. Check whether the fan power cable is damaged. If
yes, repair or replace the fan.
2. Check whether the fan is blocked. Ensure that the fan
can rotate freely.
3. Locate the problem with other fans. If the fault
phenomenon occurs only with the current fan, replace
the fan. If not, replace the PIB board.
4. Replace the fan extension cable.
5. Replace the fan.
th
May 05
, 2021

Advertisement