25004
Projector
Filter detection exception.
25005
Projector
Air inlet temperature_Low.
25006
Projector
Air inlet temperature_Too low.
25007
Projector
Air inlet temperature_High.
25008
Projector
Air inlet temperature_Too high.
25009
Projector
Air outlet temperature_Low.
Air outlet temperature_Too
25010
Projector
25011
Projector
Air outlet temperature_High.
Supra-5000 Digital Cinema and Secured Media Projection System
User Manual
1. The filter is not properly installed.
2. The filter detection switch is
abnormal.
1. The projection room temperature
is below 0℃.
2. If the temperature value does not
change, the air inlet NTC is faulty.
1. The projection room temperature
is below 0℃.
2. If the temperature value does not
change, the air inlet NTC is faulty.
1. The projection room temperature
is higher than 35℃.
2. The air inlet or air outlet of the
projector is blocked.
3. The filter of the projector is
clogged.
4. The system fan is faulty.
5. If the temperature value does not
change, the NTC is faulty.
1. The projection room temperature
is higher than 35℃.
2. The air inlet or air outlet of the
projector is blocked.
3. The filter of the projector is
clogged.
4. The system fan is faulty.
5. If the temperature value does not
change, the NTC is faulty.
The air outlet NTC may be open-
circuited or damaged.
The air outlet NTC may be open-
low.
circuited or damaged.
1. The projection room temperature
is higher than 35℃.
2. The air inlet or air outlet of the
projector is blocked.
3. The filter of the projector is
clogged.
4. The system fan is faulty.
5. If the temperature value does not
change, the NTC is faulty.
1. Re-install the filter.
2. Replace the detection switch.
1. Check the projection room temperature and ensure
that the indoor temperature is higher than 0℃.
2. Replace the air inlet NTC.
1. Check the projection room temperature and ensure
that the indoor temperature is higher than 0℃.
2. Replace the air inlet NTC.
1. Check the projection room temperature.
2. Check whether there are obstacles at the air inlet or air
outlet.
3. Check and replace the air inlet filter.
4. Check and replace the faulty system fan.
5. Replace the air inlet NTC.
1. Check the projection room temperature.
2. Check whether there are obstacles at the air inlet or air
outlet.
3. Check and replace the air inlet filter.
4. Check and replace the faulty system fan.
5. Replace the air inlet NTC.
Replace the air outlet NTC.
Replace the air outlet NTC.
1. Check the projection room temperature.
2. Check whether there are obstacles at the air inlet or air
outlet.
3. Check and replace the air inlet filter.
4. Check and replace the faulty system fan.
5. Replace the air outlet NTC.