TROUBLESHOOTING GUIDE
Problem
Tickets do
not dispense
or Wrong
Tickets on
amount
monitor does
not match
dispensed.
tickets coming
out of game.
Check for
the correct
amount of
tickets
showing on
Monitor
Tickets on
monitor do
match tickets
coming out of
game.
Tickets are empty in ticket tray
Low Tickets
message on
Faulty cable. Disconnected,
monitor
loose or broken wires.
Faulty low ticket switch.
Faulty I/O Aux Board
The top sensor is dirty.
Propeller values
Top Sensor needs
are a bit off target
calibration.
Probable Cause
Opto Sensor on ticket
dispenser dirty.
Faulty ticket dispenser.
Notch on tickets cut too
shallow.
Faulty cable. Disconnected,
loose or broken wires.
Enter Diagnostic menu and
test Dispenser
Check dipswitches on I/O
Aux Board
Faulty I/O Aux Board
Settings in Menu are
incorrect.
Propeller Sensor not
working properly.
Load tickets into tray. Ensure tickets hold down micro
switch wire.
Check connectors from low ticket switch to I/O Aux board.
Check for continuity. (CE23056)
Inspect switch and replace if needed. (AASW200)
Check dipswitches on I/O Board, Replace I/O Aux Board if
needed. AACB9605-CBL
Open the side plexi and wipe off the top sensor.
Refer to "How to Fine Tune Propeller Calibration" section.
Blow dust from sensor and clean with
isopropyl alcohol.
Replace with working dispenser to isolate the
problem. (A5TD1)
Flip tickets and load upside-down to have large
cut notch toward opto sensor.
Check connectors from ticket dispensers to I/O
Aux Board. Check for continuity.
Cables CE26011
There are many options that affect ticket payout
using the dipswitches. Refer to Dip Switch
Setting page.
Replace I/O Aux Board. AACB9605-CBL
Enter Menu and check certain areas: Preset
Ticket Pattern & Mercy tickets.
Refer to "Propeller Sensor not working properly"
section.