8.2.15 Asynchronous/Synchronous selection
•
To switch from Asynchronous to Synchronous:
Menu CONFIG DRIVE, PAR 540 Control type
04.01
DRIVE MONITOR
04.02
DRIVE INFO
04.03
DRIVE CONFIG
04.04
ALARM CONFIG
03 /18
Control type
SYN FOC
Value:
Press E to reset the drive and restart in the new operating mode.
Note !
Important: the default parameters including the LIFT application are reloaded.
This can only be done with the drive disabled.
•
To switch from Synchronous to Asynchronous:
Menu CONFIG DRIVE, PAR 540 Control type
04.01
DRIVE MONITOR
04.02
DRIVE INFO
04.03
DRIVE CONFIG
04.04
ALARM CONFIG
03 /18
Control type
ASY FOC
Value:
The example shows the selection (1) ASY FOC, other modes are available: (0) ASY SSC, (2) SYN FOC.
Press E to reset the drive and restart in the new operating mode.
Note !
Important: the default parameters including the LIFT application are reloaded.
This can only be done with the drive disabled.
x2
PAR:
540
2
x2
PAR:
540
1
ADL500 • Quick installation guide - Specifications and connection
03 /18
PAR:
540
Control type
ASY SSC
Value:
0
03 /18
PAR:
540
Control type
SYN FOC
Value:
2
03 /18
PAR:
Control type
E
ASY SSC
Value:
0
03 /18
PAR:
Control type
E
SYN FOC
Value:
2
540
540
59