Step 5 – Setting the maximum speed reference and maximum system speed
Select the unit of measurement for the speed references
●
STARTUP WIZARD
Set speeds?
E=Yes
●
Set the multispeed values
Multi speed configuration table:
Through the combination of "MtlSpd S0" (Digital input 4), "MtlSpd S1" (Digital input 5) and "MtlSpd S2" (Digital input
Attention
6) commands, is possible to select Multi speed desired, according to next table:
74
01 /08
Multi speed 0
E
Def:
Down=Next
02 /08
Multi speed 1
Def:
03 /08
Multi speed 2
Def:
04 /08
Multi speed 3
Def:
05 /08
Multi speed 4
Def:
06 /08
Multi speed 5
Def:
07 /08
Multi speed 6
Def:
08 /08
Multi speed 7
Def:
MtlSpd S2
MtlSpd S1
0
0
0
0
1
1
1
1
ADL500 • Quick installation guide - Specifications and connection
PAR:
11020
Range: -10000 ... 10000
0.10 m/s
0.10
PAR:
11022
Range: -10000 ... 10000
1.00 m/s
1.00
PAR:
11024
Range: -10000 ... 10000
0.40 m/s
0.40
PAR:
11026
Range: -10000 ... 10000
0.00 m/s
0.00
PAR:
11028
Range: -10000 ... 10000
0.00 Hz
0.00 Hz
PAR:
11030
Range: -10000 ... 10000
0.00 m/s
0.00
PAR:
11032
Range: -10000 ... 10000
0.00 m/s
0.00
PAR:
11034
Range: -10000 ... 10000
0.00 m/s
0.00
MtlSpd S0
0
0
Multispeed 0, PAR 11020
0
1
Multispeed 1, PAR 11022
1
0
Multispeed 2, PAR 11024
1
1
Multispeed 3, PAR 11026
0
0
Multispeed 4, PAR 11028
0
1
Multispeed 5, PAR 11030
1
0
Multispeed 6, PAR 11032
1
1
Multispeed 7, PAR 11034
ACTIVE SPEED