Setup
Enter SETUP and proceed to the Options Setup.
option
With option displayed, press the TARE key. The display will change to show opt=.
Proceed to the opt= parameter.
opt?
With opt? displayed, press the TARE key. The display will change to no. Press the
Fn/ key to toggle to yes and press the TARE key. The display will change to opt=.
Proceed to the opt= parameter.
Otherwise, to skip the Options Setup, press the TARE key to advance to the fUnC?.
prompt.
oPt= (Option)
Press the TARE key to show the current setting. If the setting displayed is acceptable,
press the TARE key again to save it.
Otherwise, use the Fn/▲ key to toggle to a new setting and press the TARE key to save
it. Allowable values are:
0 = No Option Card Installed
1 = Serial Interface, Ethernet, Wi-Fi, or USB Option Card Installed
2 = not applicable
3 = not applicable
4 = Digital to Analog Converter Option Card Installed
bAUd= (Optional Serial Interface Baud Rate)
Press the TARE key to show the current setting. If the setting displayed is acceptable,
press the TARE key again to save it.
Otherwise, use the Fn/ key to toggle to a new baud rate for the serial ports and press the
TARE key to save it. Allowable settings are:
12 = 1200 Baud
19 = 19.2k Baud
24 = 2400 Baud
38 = 38.4k Baud
8400-M022-O1 Rev K Model 190 Indicator
48 = 4800 Baud
76 = 76.8k Baud
96 = 9600 Baud
101