Table of Contents

Advertisement

Setup

Enter SETUP and proceed to the Options Setup.
option
With option displayed, press the TARE  key. The display will change to show opt=.
Proceed to the opt= parameter.
opt?
With opt? displayed, press the TARE  key. The display will change to no. Press the
Fn/ key to toggle to yes and press the TARE  key. The display will change to opt=.
Proceed to the opt= parameter.
Otherwise, to skip the Options Setup, press the TARE  key to advance to the fUnC?.
prompt.
oPt= (Option)
Press the TARE  key to show the current setting. If the setting displayed is acceptable,
press the TARE  key again to save it.
Otherwise, use the Fn/▲ key to toggle to a new setting and press the TARE  key to save
it. Allowable values are:
0 = No Option Card Installed
1 = Serial Interface, Ethernet, Wi-Fi, or USB Option Card Installed
2 = not applicable
3 = not applicable
4 = Digital to Analog Converter Option Card Installed
bAUd= (Optional Serial Interface Baud Rate)
Press the TARE  key to show the current setting. If the setting displayed is acceptable,
press the TARE  key again to save it.
Otherwise, use the Fn/ key to toggle to a new baud rate for the serial ports and press the
TARE  key to save it. Allowable settings are:
12 = 1200 Baud
19 = 19.2k Baud
24 = 2400 Baud
38 = 38.4k Baud
8400-M022-O1 Rev K  Model 190 Indicator
48 = 4800 Baud
76 = 76.8k Baud
96 = 9600 Baud
101

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents