Accumulated Weight Function - Cardinal 190 Installation, Technical And Operation Manual

Table of Contents

Advertisement

Accumulated Weight Function

When the accumulated weight function has been enabled during setup of the indicator, the
function must be activated before it can be used. Refer to the section, Function Setup, the
FUnC (FUnC?) parameter to enable the Fn/ key Hold function.
NOTE: If Legal-For-trade (LFt=yes) has been selected in setup, the Gross weight
must return to zero before the next weighing operation to enable accumulation.
Activate Accumulated Weight Function
Press and hold the Fn/ key until the display blanks.
1.
Once the display blanks, release the Fn/ key
2.
The display will change to show ACCU X, the prompt, and status of the Accumulated
3.
Weight function.
If the setting displayed is acceptable, press the TARE  key to save it. Otherwise, use
4.
the Fn/ key to toggle to a new setting and press the TARE  key to save it.
1 = Accumulated Weight Function Active
0 = Accumulated Weight Function Not Active
Repeatedly press the TARE  key to step through the remaining function prompts until
5.
the indicator returns to the weight display.
Accumulated Weight Function Operation
During operation, the weight recorded when the PRINT key is pressed will be added to the
accumulator. This will be indicated by totAL being displayed briefly after the PRINT key
has been pressed.
To display the Accumulator, simultaneously press the UNITS/ and TARE  keys. If
1.
Legal-For-trade (LFt=yes) is on, the gross load must be zero.
The Gross accumulator weight will be shown as indicated by the alternating G and A.
2.
After a brief interval, the display will show the number of Gross weight items
3.
accumulated, indicated by the alternating G and C.
The display will alternate between showing the Gross accumulator weight and the
4.
Gross accumulator count.
Press the TARE  key and the Net accumulator weight will be displayed, indicated by
5.
the alternating n and A.
After a brief interval, the display will show the number of Net weight items accumulated,
6.
indicated by the alternating N and C.
The display will alternate between showing the Net accumulator weight and the Net
7.
accumulator count.
Press the TARE  key to display the Gross accumulator again.
8.
Press the ZERO key to clear the displayed accumulator.
9.
Press the NET/GROSS key to return to the normal weight display.
10.
68
8400-M022-O1 Rev K  Model 190 Indicator

Hide quick links:

Advertisement

Table of Contents
loading