2.2. Indicator Setup

Setup Data Entry

8200-M639-O1 Rev D 09/14
Your Model 212/212X indicator has been thoroughly tested and
configured before being shipped to you. If the indicator is being
connected to a scale for the first time or re-configuration is necessary
for other reasons, proceed as indicated.
DO NOT operate the keypad with pointed objects (pencils,
pens, etc). Damage to keypad resulting from this practice is
NOT covered under warranty.
Figure No. 14
During the indicator setup and configuration process it will be necessary to
enter operational parameters via the 212/212X keypad.
Press the F key and then the 0/NO key to enter quick calibration or
setup and configuration.
Press the ENTER key to step through the parameters in each menu.
With a setting for a parameter displayed, press the ENTER key alone
to save the displayed setting and advance to the next prompt.
To change a setting, enter a new value and press the ENTER key.
This will save the new value and advance to the next prompt.
Pressing the  (asterisk) key will "backup" to the previous prompt.
NOTE: Setup may be interrupted at any time. ALL data
previously entered and finalized with the ENTER key will be
retained in the non-volatile memory.
To exit setup, press the  key with any menu selection displayed or cycle
power at any time (press the ON/OFF key twice).