4.4.4 Changing the Table Plate
The NC-rotary table can be equipped with any of
two different table plates. In order to change the
table plate, proceed as follows:
Remove Table Plate
• Turn the table plate to the zero position.
• Enter the command M 25 in the „Manual" mode.
The table clamping is released.
• Loosen all table plate holding screws and remove
the large front covering plate [1].
• Remove both side covering plates [2]. The table
plate clamping mechanism is located under these.
• Loosen the four hexagonal screws [3] (13 mm ) on
each side and remove the brass clamps [4] from
the holder [5].
• With a pulling-off device, pull the two cylindrical
pins [6] vertically upwards out of the table plate.
4.4.4
3
4
• Loosen the 8 holding bolts [7] (M 12) in the
upper surface of the table plate and remove them.
• Tighten the two eye bolts with inserted tongues at
the ends of the center T-groove and lift the table
plate with suitable lifting tackle.
Note
When putting the table plate down ensure that the
plate does not lie directly on its underside as the
graduated strip projects downwards a little.
Treat all exposed areas of the table with a rust
prevention agent.
Lay the plate down on its upper surface or push
suitable backing material under the plate, so that
the graduated strip is not damaged.