Hermle Z 160 M Instruction Manual

Hermle Z 160 M Instruction Manual

Microlitre centrifuge

Advertisement

Quick Links

Instruction Manual
for
Microlitre Centrifuge
Z 160 M
Brushless Motor

Advertisement

loading

Summary of Contents for Hermle Z 160 M

  • Page 1 Instruction Manual Microlitre Centrifuge Z 160 M Brushless Motor...
  • Page 3 Table of Contents Notes: General Information Installation Installing the Rotor Operation Service and Maintenance Troubleshooting Where to call Determination of g-Values...
  • Page 4 Determination of g-values Spinning radius in cm Speed (RPM) per minute 20000 15000 Relative centrifugal force in g 10000 30000 20000 6000 10000 5000 4000 4000 3000 2000 3000 1000 2000 1000...
  • Page 5 Where to call General Information 1.1 Description 1.2 Safety precautions Note: All users of the centrifuge must read the Safety Precautions section before attempting to operate the unit! If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
  • Page 6 Troubleshooting guide Centrifuge will not start 1.3 Technical Data Possible reason: No power supply Possible reason: Blown fuse Lid lock will not release Possible reason: Defective lid lock Possible reason: No power from PC board 1.4 Accessories supplied with each centrifuge unit Possible reason: Lid lock is jammed Possible reason:...
  • Page 7 Service and Maintenance 5.1 Centrifuge service Installation 2.1 Unpacking the centrifuge 5.2 Cleaning the centrifuge 5.3 Disinfection 2.2 Required space 5.4 Replacing fuses...
  • Page 8 2.3 Installation ATTENTION: The timer must be in the OFF position before connecting the power cord. Failing to place the timer in the off position may result in 4.4 Speed selection damage to the centrifuge and injury to personnel. “speed” Installing the rotors 3.1 Rotors and accessories 4.5 Selection of operating time and momentary operation...
  • Page 9 3.2 Mounting and securing the angle rotor time lid lock minutes hold speed rpm x 1000 quick Note: Figures 1 and 2 can be found on the following pages. 4.1 Closing the lid 4.2 Lid release WARNING: Do not attempt to open the lid of any centrifuge until the unit has come to a complete stop.
  • Page 10 3.4 Overloading rotors right! Failure to reduce the speed may result in damage to the rotor and centrifuge. wrong! Operation ATTENTION: Never attempt to operate the centrifuge with rotors or adapters that show signs of corrosion or mechanical damage. Never centrifuge strongly corrosive materials that may damage the rotors or accessories.