Key Lock Function; Pro Mode Setting - Panasonic HG-C Series Insruction Manual

Micro laser distance sensor (cmos)

Advertisement

Zero set release
Press the UP and
DOWN key
simultaneously for 6
seconds.
will be displayed
during this period.
The setting or releasing of the zero set from an external input operates as in
the following figure.
>10ms
OFF
ON
Zero set setting
When the power is turned ON again, zero set from external input can be
released. At this time, the zero set will not be saved.
Even when the zero set is set in the sensor, the zero set can be set or
released from an external input. However, when the power is turned ON
again, the zero set set in the sensor will be displayed.
11

Key lock function

The key lock function is to prevent acceptance of key operations, so that
the conditions in each setting mode are not changed accidentally.
When the key operation is performed after the key lock is set,
displayed on the digital display.
Key lock setting
Press the TEACH
key and DOWN key
simultaneously for 3
seconds.
Key lock release
Press the TEACH
key and DOWN key
simultaneously for 3
seconds.
12

PRO mode setting

Part description
1
2
4
3
No.
Item
PRO indicator (Yellow)
1
DOWN key (Select)
2
UP key (Select)
3
TEACH key (Confirmed)
4
All manuals and user guides at all-guides.com
Arrow description in figures
Automatic
Press the DOWN key for 3 seconds or more to switch to PRO MODE. The
PRO indicator (yellow) will turn ON when the PRO MODE is active. To re-
turn to the measurement display, press the DOWN key again for 3 seconds
or more.
1s
Zero set release
"
will be
"
Automatic
Automatic
5
Arrow
Description
Press the TEACH key
Press UP key or DOWN key
Press DOWN key
Setting
Default setting
Description
Set the response time.
Response
"
speed
"
"
Output
Select the control output operation mode.
operation
"
Set the sensing output.
"
"
mode)
Sensing
"
output
mode)
"
mode)
"
"
Set the output operation of the analog output
Analog
"
output
"
HG-C1030:
Set the hysteresis width.
HG-C1050:
HG-C1030: 0.001 to 5.00mm
HG-C1050: 0.01 to 15.00mm
HG-C1100:
Hysteresis
HG-C1100: 0.02 to 35.00mm
HG-C1200: 0.1 to 80.00mm
HG-C1200:
HG-C1400: 0.2 to 200.00mm
HG-C1400:
Set the external input.
"
External
"
input
"
"
Set the timer operation. The timer time is fixed
at 5ms.
"
Timer
"
"
"
The display of the measured value can be
changed.
Display
"
"
"
Set the control output and the analogue output
operation when a measurement error occurs
(insufficient light intensity, saturation of light
Hold
intensity, out of measurement range).
"
"
The digital display can be set to go OFF when
key operation is not performed for 30 seconds.
ECO
Current consumption can be reduced.
"
"
Return to the default setting (factory setting).
Reset
"
"
": High precision 10ms
": Standard 5ms
": High speed 1.5ms
": Light-ON, "
": Dark-ON
": Normal sensing mode
": 1-point teaching (Window comparator
": 2-point teaching (Window comparator
": 3-point teaching (Window comparator
": Trailing differential mode
": Trailing differential mode
": Analog voltage output (0 to +5V)
": Analog current output (4 to 20mA)
": Zero set function,
": Teaching function
": Light emitting stop function
": Trigger function
": No timer,
": OFF-delay timer
": ON-delay timer
": One-shot timer
": Normal
": Invert
": Offset
": Hold OFF
": Hold ON
": ECO OFF
": ECO ON
": Reset NG
": Reset OK