Appendix; Technical Data - Sungrow SG2.0RS-S User Manual

1-phase pv grid-connected inverter
Hide thumbs Also See for SG2.0RS-S:
Table of Contents

Advertisement

10 Appendix

10.1 Technical Data

P P a a r r a a m m e e t t e e r r
I I n n p p u u t t ( ( D D C C ) )
Recommended max. PV
input power
Max. PV input voltage
Startup voltage
Nominal input voltage
MPP voltage range
No. of MPPTs
Default No. of PV strings
per MPPT
Max. PV input current
Max. current for input
connector
Max. DC short-circuit
current
Max. inverter backfeed
current to strings
O O u u t t p p u u t t ( ( A A C C ) )
Nominal AC output power
Max. AC output apparent
power
Max. AC output current
Max. inrush current (peak/
duration)
Max. output fault current
(peak/duration)
Nominal AC voltage
AC voltage range
Nominal grid frequency /
Grid frequency range
Harmonic (THD)
76
S S G G 2 2 . . 0 0 R R S S - - S S
S S G G 2 2 . . 5 5 R R S S - - S S
3.0 kWp
3.75 kWp
600 V
*
50 V
360 V
40 V–560 V
1
1
16 A
20 A
20 A
0 A
2000 W
2500 W
2000 VA
2500 VA
9.1 A
11.4 A
8 A / 12 ms
80 A / 3.2 us
220 V / 230 V / 240 V
154 V AC–286 V AC
50 Hz / 45 Hz–55 Hz, 60 Hz / 55 Hz–65 Hz
< 3 % (of nominal power)
S S G G 3 3 . . 0 0 R R S S - - S S
4.5 kWp
3000 W
3000 VA
13.7 A