5 Electrical Connection
• The PV strings to two DC input areas may differ from each other, including PV
module type, number of PV modules in each string, angle of tilt, and installation
orientation.
Prior to connecting the inverter to PV inputs, the specifications in the following table
should be met:
I I n n v v e e r r t t e e r r M M o o d d e e l l
All models

5.6.2 Assembling the PV Connectors

High voltage may be present in the inverter!
• Ensure all cables are voltage-free before performing electrical operations.
• Do not connect the AC circuit breaker before finishing electrical connection.
SUNGROW provides corresponding PV connectors in the scope of delivery for
quick connection of PV inputs. To ensure IP65 protection, use only the
supplied connector or the connector with the same ingress of protection.
Step 1 Strip the insulation from each DC cable by 7 mm–8 mm.
Step 2 Assemble the cable ends with the crimping pliers.
28
F F i i g g u u r r e e 5 5 - - 3 3 PV Input Configuration (SG6.0RS for example)
O O p p e e n n - - c c i i r r c c u u i i t t V V o o l l t t a a g g e e L L i i m m i i t t
600 V
M M a a x x . . c c u u r r r r e e n n t t f f o o r r i i n n p p u u t t c c o o n n n n e e c c t t o o r r
20 A