Sungrow SG2.0RS-S User Manual page 74

1-phase pv grid-connected inverter
Hide thumbs Also See for SG2.0RS-S:
Table of Contents

Advertisement

7 iSolarCloud App
Table 7-6 "Q(P)" Mode Parameters Explanation
P P a a r r a a m m e e t t e e r r
Q(P) Curve
QP_P1
QP_P2
QP_P3
QP_K1
QP_K2
QP_K3
QP_
EnterVoltage
QP_
ExitVoltage
QP_
ExitPower
QP_
EnableMode
* Curve C is reserved and consistent with Curve A currently.
" " Q Q ( ( U U ) ) " " M M o o d d e e
64
E E x x p p l l a a n n a a t t i i o o n n
Select corresponding curve according to local
regulations
Output power at point P1 on the Q(P) mode curve
(in %)
Output power at point P2 on the Q(P) mode curve
(in %)
Output power at point P3 on the Q(P) mode curve
(in %)
Power factor at point P1 on the Q(P) mode curve
Power factor at point P2 on the Q(P) mode curve
Power factor at point P3 on the Q(P) mode curve
Voltage for Q(P) function activation (in %)
Voltage for Q(P) function deactivation (in %)
Power for Q(P) function deactivation (in %)
Unconditional activation/deactivation of Q(P)
function
F F i i g g u u r r e e 7 7 - - 1 1 7 7 Reactive Power Regulation Curve in Q(P) Mode
User Manual
R R a a n n g g e e
A, B, C
*
20.0 %–100.0
%
20.0 %–100.0
%
20.0 %–100.0
%
Curve A/C:
0.800 to 1.000
Curve B: -0.600
to 0.600
100.0 %–110.0
%
90.0 %–100.0
%
1.0 %–20.0 %
Yes, No

Advertisement

Table of Contents
loading