Appendix; Technical Data - Sungrow SH5T User Manual

3–phase hybrid inverter
Table of Contents

Advertisement

11 Appendix

11.1 Technical Data

Parameters
Input (DC)
Recommended max. PV in-
put power
Max. PV input voltage
Min. PV input voltage / Start-
up input voltage
Rated PV input voltage
MPP voltage range
MPP voltage range for rated
power
No. of independent MPP
trackers
No. of PV strings per MPPT
Max. PV input current
Max. DC short-circuit current
Max. current for input
connector
Battery Data
Battery type
Battery voltage
Max. charge / discharge
current
Max. charge / discharge
power
Input and Output (AC)
Max. AC power from grid
Max. AC input power
Max. AC output apparent
power
Max. AC output current
Rated AC voltage
AC voltage range
SH5T
10000 Wp
1000 V
150 V / 180 V
600 V
150 V - 950 V
225 V - 850 V
1 / 1
32 A (16 A / 16 A)
40 A (20 A / 20 A)
30 A
Li-ion battery
100 V - 700 V
50 A */ 50 A *
15000 W / 5000 W
43000 VA
5000 W
5000 VA
7.6 A
3 / N / PE, 220 / 380 V; 230 / 400 V; 240 / 415 V
270 - 480 V
SH6T
12000 Wp
270 V - 850 V
2
15000 W / 6000 W
6000 W
6000 VA
9.1 A
117