Installing an expansion board in the secondary riser cage
Installing an expansion board in the secondary riser cage
Use these instructions to install expansion boards such as Smart I/O cards (such as DSC-25 2-port SFP28 cards), solid state NVMe/PCIe
Add-In-Cards, HBAs, CNAs, InfiniBand adapters, and accelerators.
Prerequisites
Prerequisites
Before installing this option, be sure that you have the following:
The components included with the hardware option kit
T-10 Torx screwdriver
Procedure
Procedure
1. Observe the following alerts:
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
WARNING:
internal system components to cool before touching them.
CAUTION: To prevent damage to electrical components, properly ground the server before beginning any
CAUTION:
installation procedure. Improper grounding can cause electrostatic discharge.
2. Back up all server data.
3. Power down the server (Power down the server).
4. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
5. Do one of the following:
a. Extend the server from the rack .
b. Remove the server from the rack .
6. Remove the access panel .
7. Install a secondary riser cage:
Low-profile (Installing a secondary low-profile PCIe slot riser cage option )
Full-height (Installing a secondary full-height PCI riser cage option )
8. Remove the expansion slot blank:
A T-10 Torx screwdriver is required to remove the expansion slot blank.
Half-length
Installing an expansion board in the secondary riser cage
103