Installing The Systems Insight Display Power Module - HP HPE ProLiant DL365 Gen10 Plus Server User Manual

Hide thumbs Also See for HPE ProLiant DL365 Gen10 Plus Server:
Table of Contents

Advertisement

Installing the Systems Insight Display power module

Installing the Systems Insight Display power module
Prerequisites
Prerequisites
Before installing this option, be sure you have the following:
The components included with the hardware option kit
T-10 Torx screwdriver
Procedure
Procedure
1. Observe the following alerts:
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
WARNING:
internal system components to cool before touching them.
CAUTION: To prevent damage to electrical components, properly ground the server before beginning any
CAUTION:
installation procedure. Improper grounding can cause electrostatic discharge.
2. Back up all server data.
3. Power down the server (Power down the server).
4. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
5. Do one of the following:
a. Extend the server from the rack ( Extend the server from the rack ).
b. Remove the server from the rack ( Remove the server from the rack ).
6. Remove the access panel ( Remove the access panel ).
7. Disconnect the Power/UID/USB cable from the front power button/USB 3.0 on the system board.
8. Using a Torx T-10 screwdriver, remove the Power/UID/USB assembly.
Installing the Systems Insight Display power module
128