Function of Auxiliary Output

AUXOUT=0: Ready output
Application: Used to confirm when the judgment result of imaging is
output by a new bank after bank is switched.
Bank switch
Internal operation
Imaging
Aux. output
Aux. output
Turns OFF when bank switch input changes.
Turns OFF when bank switch input changes.
Judge output
Previous condition
AUXOUT=1: Judgment timing output
Application: Used to output judgment result at specified timing by imaging
a work by synchronization input signal for the image-taking
with synchronization input signal.
Synch. input
Pixel reset
Internal operation
Aux. output
AUXOUT=2: Lighting output
Application: Used when turning ON a light other than exclusive external
light (CVS-LW1) only when taking image for the imaging
using a synchronization input signal.
Synch. input
Pixel reset
Internal operation
Aux. output
AUXOUT=3: Position / Magnification / Rotation correction allowable
range output
Application: Used to measure the distance between the work and sensor,
angle, and position.
Internal operation
Imaging
Aux. output
Ramco Innovations
Compare
Bank switching
Image condition
Compare
Imaging
Compare
Imaging
Compare
Compare
Imaging
Turns ON when the values for which the position, magnification, and rotation corrections are performed are
within the set values of "MAGNIFY%", "POSIT X%", "POSIT Y%", and "ROTATE%".
When the set value of "MAGNIFY" is "0", turns ON only when the values for which the position
and rotation corrections are made are within corresponding set values.
www.optex-ramco.com
Compare
Imaging
Pixel reset
Reversed every time judgment output is renewed.
Pixel reset
Compare
Imaging
phone 800-280-6933
APPENDIX
Compare
Imaging
Turns ON when the first judgment
Turns ON when the first judgment
result bank switch is output.
result bank switch is output.
Image condition
Compare
Imaging
Compare
Imaging
Compare
Imaging
69