Function Setting - Optex SIP-3020/5 Installation Instructions Manual

Synthesized intelligent pir redwall-v series
Table of Contents

Advertisement

5

FUNCTION SETTING

Applicable
SIP-3020/5
models
Far area sensitivity selector
switch
Walk tester
connector
Sens.Select.SW.
Sens.Select.SW.
573050
573050
Far area Near area
Far area
Near area Creep zone
Creep zone
Alarm Creep
Alarm
Creep
UP DWN
Operation indicator
(See Step .)
Cautions>>
If the red LED keeps blinking for approx. 60 seconds
after turning the power on, turn the power off and then on
again.
5-
Sensitivity Selector Switch for Far
Area, Near Area and Creep Zone
Applicable
SIP-3020/5
models
You can change the sensitivity for far area
detection, near area detection and creep zone
detection independently.
SELECTOR
POSITION
Sens.Select.SW.
Sens.Select.SW.
SH
Far area Near area
Far area
Near area Creep zone
Creep zone
H
M
(Factory
default)
L
5-2
Detection Logic Selector Switch
Applicable
SIP-3020/5
models
Detection area of SIP-3020/5, SIP-400/5
and SIP-404/5 consist of two types of plane
detection areas in an alternative manner
constructed by two pairs of pyro-elements, for
the near and the creep zone.
UP
SELECTOR
STATUS
POSITION
DWN
OR
UP
(
Factory
default
DWN
AND
SIP-4010/5
SIP-404/5
Near area sensitivity
selector switch
Creep zone
sensitivity selector
switch
Sens.Select.SW.
Sens.Select.SW.
573050
573050
Far area Near area
Far area
Near area Creep zone
Creep zone
Alarm Creep
Alarm
Creep
UP DWN
:
Detection logic selector
(AND or OR)
2:
Detection range selector switch
3,4: Alarm holding time selectors
SIP-4010/5
SIP-404/5
FUNCTION
Suitable for sites requiring a
level of sensitivity higher than
"H"
Suitable for sites requiring a
level of sensitivity higher than
"M"
Suitable for standard
applications
Suitable for hostile and narrow
area
Dip switch
SIP-4010/5
SIP-404/5
FUNCTION
A sensor signal is output when an
object is detected in either of the two
detection areas.
)
* Use this mode when you adjust
the detection area. Switch to AND
mode after you have finished the
detection area adjustment.
Use this mode to reduce instances
of incorrect detection of objects. The
sensor signal is output only when
an object is detected within the two
detection areas. If any objects are
blocking multiple detection areas,
use OR mode.
5-3
Detection Range Selector Switch
SELECTOR
UP
POSITION
DWN
Tamper
switch
Applicable
models
[ft.]
[m]
3
4
0
2
0
0
0
0
0
20
Applicable
models
[ft.]
[m]
3
4
0
2
0
0
0
0
0
20
Cautions>>
If you cancel the far area detection, the detection
distance is limited to approximately 20 meters (65ft.). Be
sure to readjust and check the detection area using the
area viewfinder and the walk tester.
5-4
Alarm Interval Switch
Applicable
models
1
* UL-5: If movement occurs continuously during the time interval directly after the first
alarm, the time period for no alarms starts over.
- 6 -
STATUS
FUNCTION
Cancels the far area detection. The
UP
OFF
detection area is reduced as shown
below.
ON
(
)
DWN
Factory
Enables the far area detection.
default
SIP-3020/5
SIP-4010/5
Far area detection is canceled.
0
20
30
40
50
60
70
80
90
SIP-3020/5
SIP-4010/5
Far area detection is canceled.
0
20
30
40
50
60
70
80
90
SIP-3020/5
SIP-4010/5
You can set an interval (4 different times) to
suspend the alarm signal output.
For example, if you set this interval to 30
seconds, no more alarm signals will be output
for 30 seconds after the output of the first alarm
signal. If no pedestrians are detected for more
than 30 seconds, the system returns to the
standby mode.
Then, when a pedestrian is detected, the alarm
signal will be output.
SELECTOR
POSITION
0 sec
(Factory
FUNCTION
5 sec 30 sec 60 sec
default)
2
Dip switch
SIP-404/5
30
40 [m]
00
0
20
30[ft.]
SIP-404/5
30
40 [m]
00
0
20
30[ft.]
3-4
Dip switch
SIP-404/5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sip-4010/5Sip-404/5

Table of Contents