Function name
LCD display
Image sensor
gain*
1
IMG GAIN
Magnification
correction
tolerance*
1
MAGNIFY%
Horizontal
position correction
tolerance*
1
POSIT% X
Vertical position
correction
tolerance*
1
POSIT% Y
Rotation
correction
tolerance*
1
ROTATE%
*1:When bank is switched, the set value also changes.
Ramco Innovations
Setting range
(Initial value)
Sets the gain of the image sensor. Though the
0 – 63
screen gets brighter as the value increases, the
screen noise also increases. Increase the value
(0)
when trying to shorten the shutter time.
Sets the tolerance of the magnification and
reduction. Correction can be done up to the ratio
of 128 / (128±Set value). When set to "0",
magnification & reduction correction is not
executed.For example, when set to "40",
correction is made within the range of 0.76 - 1.45
0 – 127
times since the ratio is 128 / (128±40)When
colors for both the position correction and the
(0)
rotation correction are registered, correction is
made based on the distance of each color. And
when a color for the position correction only is
registered, correction is made based on the color
area of that color.No correction is made when
neither one of colors is registered.
Sets the tolerance of the horizontal position
correction. Corrects up to the set value ±
pixels.When set to "0", no horizontal position
0 – 208
correction is made. Correction is made when
(104)
a color for the position correction is registered,
and no correction is made when no color is
registered.
Sets the tolerance of the vertical position
correction. Corrects up to the set value ±
pixels.When set to "0", no vertical position
0 – 236
correction is made. Correction is made when
(118)
a color for the position correction is registered,
and no correction is made when no color is
registered.
Sets the tolerance of the rotation correction.
Corrects up to the set value ±angle.When set
to "0", no rotation correction is made. With the
0 – 180
initial value "180", correction is made up to ±
(180)
180° (360°).Rotation correction is made only
when colors for both the position and rotation
corrections are registered.